FAIRCOAT DAMPPROOF – DAMPPROOF COATING FOR INTERNAL WALLS, CEILINGS AND RCC WATER TANKS

Why do we need water proofing? There is a simple answer to this.
Water proofing is required to stop the ingress of water in the structure making it water resistant. It acts as a protective coating from other elements as well such as oil and grease, chemical attacks, acid rain etc. The dual purpose of Faircoat Damproof allows us to achieve both our purposes of waterproofing and protective coating.

Faircoat Dampproof is best suited when used to protect the internal wall, ceilings etc from all possible attacks of dampness, leakage to the structure & also when you need an antimicrobial coating. It is widely used to prevent any leakage of oil and chemicals from bund areas where large quantity of such harmful substance is stored. We all have come across external walls where graffiti art is done which is extremely difficult to remove. Faircoat Damproof is the absolute solution, as it is easily cleanable and hygienic. Hence, maintaining the clean look of the structure.
Being environmental friendly and of very low odour is it easy to apply.

Faircoat Dampproof is a 2 component material off white colour material. The Base and hardener is required to be mixed using a mechanical tool. The component can be thinned down by adding water to it, not more than 20-30% by volume of total material. To make the surface more even and to achieve a putty like finish add white cement by 20-30%.

Before applying Faircoat Dampproof to the structure it is necessary to make sure that the substrate is completely free from any kind of contamination such as oil, grease, paint etc. After the surface cleaning is complete, it is required to fill all the hole on the substrate cause by air trapped on the face of the formwork during pouring or any kind of pin holes present using Fairscreed VF (a concrete repair compound).

Minimum two coats are required to achieve the desired results. The pot life of Faircoat Dampproof is 80 minutes at 20ºC. Apply the first coat using a spray (airless), brush or roller. After the application of first coat to achieve a non slip finish spread silica sand on the wet surface and let the surface dry for a minimum of 18 hours before applying 2nd coat. The overall thickness of both the coats shall be 200-250 micron, with and approximate coverage of 0.20 – 0.25kg/m2.
In case the substrate is in damp condition a priming material such as Safecore WB primer shall be applied before the application of 1st coat of Faircoat Dampproof.

Salient Features:
• Provides excellent resistance to water, oil , grease and other solvents etc
• Odourless material
• It is Non flammable, Non toxic and Non- Hazardous
• It is easily cleanable and possesses anti fungal properties
• It can be applied on both dry and damp surfaces
• Have good adhesion to concrete

FLOWGROUT HES – CEMENTITIOUS, HIGH EARLY STRENGTH, FLOWABLE FAST SETTING GROUT

Benefits
1. High early strength (even at low temperatures).
2. Very good flow characteristic.
3. Fast set times & fast strength gain.
4. Consistency can be adjusted as per requirement.
5. High 28 day strengths.
6. Does not bleed or segregate.
7. Very good impact and thermal resistance.
8. Non corrosive to steel or iron.
9. Excellent bond strength.
10. Pre-packed factory controlled to overcome site batched variations
11. Does not contains any corrosive chemicals

Description
FLOWGROUT HES is a blend of special cement, selected and graded aggregates and Fairmate admixtures, enabling it to achieve high strengths in short time frame.

Recommended Uses
FLOWGROUT HES is useful for wide range of applications where fast strength is required, like:
1. Machine bedplates.
2. Anchoring bolts.
3. Bridge bearing pads.
4. Pre-cast concrete sections.
5. Cavities, gaps and recesses.

Application Instructions
Surface Preparation: All surfaces must be clean, sound and free from dust, ice, oils, grease or other surface contaminants such as curing membranes and form release agent etc. Bolt holes and fixing pockets should be free of dirt and debris by air blasting. For maximum bond, surfaces should be abraded or roughened, preferably by mechanical means such as needle gun, grit blasting, grinding etc. All prepared surfaces must be saturated with water several hours prior to grouting, ensuring it is free of any surface water or puddles.

Temperature control :
Temperature affects setting time and rate of increase for strength. For optimum performance maintain grout, concrete and/or steel substrates within the range of 25-30ºC prior to, during, and for 48 hours after placement of the grout.

Mixing Equipment :
FLOWGROUT HES is must be mechanically mixed using a mechanical grout mixer or a suitable drum mixer. The grout mixer will reduce the chances of the mix becoming lumpy or aerated.

Mixing Method:
1) 4 Liters of clean water per 25 kg bag of grout.
2) Add the powder component to approximately 80% of the total amount water component while mixing.
3) Add the remaining 20% of the water component to the grout at a steady rate while continuing to mix.
4) Mix until the grout appears homogenous (3-5 minutes). Allow to stand so any entrapped air can escape. Do not add more water to increase flow of the grout if a mix has stiffened due to time delays. If the grout is unworkable discard.

FAIRCURE WC – WHITE PIGMENTED CONCRETE CURING AID

Buildings have major environmental impacts over their entire life cycle. Resources such as ground cover, forests, water, and energy are depleted to give way to buildings. A green building depletes the natural resources to the minimum during its construction and operation. The aim of a green building design is to minimize the demand on non-renewable resources, maximize the utilization efficiency of these resources, when in use, and maximize the reuse, recycling, and utilization of renewable resources. It maximizes the use of efficient building materials and construction practices; optimizes the use of on-site sources and sinks by bio-climatic architectural practices; uses minimum energy to power itself; uses efficient equipment to meet its lighting, air-conditioning, and other needs; maximizes the use of renewable sources of energy; uses efficient waste and water management practices; and provides comfortable and hygienic indoor working conditions. In sum, the following aspects of the building design are looked into in an integrated way in a green building.

* Site planning
* Building envelope design
* Building system design ((HVAC) heating ventilation and air conditioning, lighting, electrical, and water heating)
* Integration of renewable energy sources to generate energy onsite.
* Water and waste management
* Selection of ecologically sustainable materials (with high recycled content, rapidly renewable resources with low emission potential, etc.).
* Indoor environmental quality (maintain indoor thermal and visual comfort, and air quality)

DESCRIPTION:
FAIRCURE WC is supplied as a white pigmented, non-staining, non toxic aqueous solution which when applied to fresh concrete surfaces, reacts with free lime and seals the pores, thus reducing the evaporation of water from the mix which assists curing process and increasing durability. Applied surfaces can be easily identified due to white pigment. Only single coat is sufficient for complete curing process eliminating the water curing.

USES:
FAIRCURE WC is a white pigmented concrete curing aid which eliminates water curing and when applied to structures can be identified easily. It helps the curing process by preventing evaporation and helps to attain strength and durability. Used for large concrete surface areas such as floors, screeds, granolithic topping, sloped slabs and vertical structures.

BENEFITS:
* Ready to use
* Can be easily applied with brush or spray.
* Can be easily identified
* Does not form film
* Single coat application
* Replacement of water curing
* Cost effective
* Non-toxic and non flammable
* Chloride free.

INSTRUCTIONS FOR USE
FAIRCURE WC should be stir before use to ensure dispersion of settled material. Apply in a continuous film using a high volume low pressure spray. At the time of spraying, nozzle of spray should be held approximately 450 mm from the concrete surface and should be sprayed evenly on the concrete surface. After spraying, no further application of water or other material is necessary to ensure further curing. When used as a curing aid, apply to edges after forms are removed under the conditions of excessive heat or drying wind, polythene, sheet may be used to cover the surface after application of FAIRCURE WC.

Equipment
Designed for ease of use and spray-ability. Application can be achieved using either hand or power operated pressure spray equipment with fan-type nozzle attachments. FAIRCURE WC may also be applied by brush or roller.

PACKING & COVERAGE: FAIRCURE WC is supplied in 1, 50, 10, 50, 100, 200 liters carboys. FAIRCURE WC will cover an area of 5 to 6 m² per litre with specified single coat.